How do I model a High Performance Attic as described in the Energy Code?

Select an Attic roof assembly that has the appropriate level of ceiling insulation in the EnergyPro Assembly library.  For a high performance attic with above deck insulation edit the input for “Above Deck Insulation” (or if doing Prescriptive compliance “Exterior Insulation”) and put in an R-Value for the insulation.  For a high performance attic with below deck insulation edit the input for “Below Deck Insulation” (or if doing Prescriptive compliance “Interior Insulation”) and put in an R-Value for the Insulation.

If you do the below deck approach, you should not include a radiant barrier since the insulation will be up against the barrier and will negate the product effectiveness.


Categories: 4. Single Family Title 24